Hello, welcome to the official website of Wuhan wenli photoelectricity technology co.! Chinese | English

Customer Service Hotline

13807131859

NEWS

NEWS Your location: Home > NEWS
Introduction to the application of infrared thermal image thermometer

 non-contactstyleinfraredThermal imageTemperature measurementTechnology has been continuously developed in recent ten years, except for the traditional steelmaking in the steel industry.high-temperatureAnd the chemical industry is toxic.environmentOutside, it has been widely used in many fields.infrared radiation thermometerThe scope of application is constantly expanding, in product quality control andmonitor, equipmentbreakdownIt plays an important role in diagnosis and energy saving.infrared radiation thermometerHas been proved to be detection and diagnosis.electronequipmentbreakdownAn effective tool for. Can save a lot of money, withinfrared radiation thermometer, can be diagnosed continuously.electronConnection problem: by looking up theDCbatteryThe hot spot at the connection of the upper output filter can detect uninterrupted.Power Supply (UPS) functional status; Can also be tested.batteryComponents andpowerThe distribution board terminals, switch gears or fuses are connected to prevent energy consumption. Since a loose connector generates heat,infrared radiation thermometerHelps identify the loop interrupter.insulatebreakdownOr monitoringelectronCompressor; Daily scanning of transformer hot spots can detect cracked windings and terminals.

1、Why use it?infrared radiation thermometer?

 

infrared radiation thermometerIt has the characteristics of convenience in use:infrared radiation thermometercanfastprovidetemperature measurement, in use thermocoupleget in touch withstylethermometermeasureWithin the time of a leakage connection point, useinfrared radiation thermometerAlmost all connection points can be read.temperature. commoninfrared radiation thermometerSolid and lightweight, it can be carried at any time in factory inspection and daily inspection..infrared radiation thermometermeasuretemperatureRelatively accurate:infrared radiation thermometerAccuracy is generally inWithin 1℃, this performance is particularly important for preventive maintenance, such as monitoring bad production conditions and special events that will lead to equipment damage and shutdown. useinfrared radiation thermometer, butfastDetection operationtemperatureSmall changes in the bud can solve the problem, reduce the equipmentbreakdownThe scope of expenses and maintenance..
 infrared radiation thermometerSafe in use:infrared radiation thermometerCan safely read inaccessible or unreachable targets.temperature, which can be found atinstrumentRead the target within the allowed range.temperature.non-contacttemperature measurement It can also be used in unsafe orget in touch withTemperature measurement More difficult areas

2、infrared radiation thermometerApplication in HVAC and refrigeration industry.

 

existHVAC/R (heating, ventilation, air conditioning and refrigeration) industry,infrared radiation thermometerHas been the most effective assistant for installation and maintenance personnel, inHVACDuring installation and maintenance, they useinfrared radiation thermometermainmeasureThe following items:
  1、
measureHeating/freezewaterpipelinethermal-protective coatingtemperature;
  2、
testThermal insulation return pipe;
  3、
testFuse and bus connector;
  4、
testElectrical connector;
  5、
testbearing;
  6. Check the application of liquid circulation heating or cooling;
  7、
testHeat insulation of water heater;

8、measureDischarge of fences, air outlets or diffuserstemperature;
9, check
permanentOverheating on the throttle or evaporator equipped with capillary tube;

Check the air of evaporator equipped with expansion valve.emptyairThe supercooling situation in the system.


3、infrared radiation thermometerIn-plantbreakdownApplication and precautions in diagnosis

 

equipmentbreakdowninfraredThe core problem of diagnosis requires accurate acquisition of the measured equipment.temperatureDistribution orbreakdownmutuallyClose pointtemperatureValue and temperature appreciation. thistemperatureInformation is not only to judge whether the equipment is available or notbreakdownThe basis, but also the judgment.breakdownThe objective basis of attribute, location and severity. Therefore, for the equipment under testbreakdownRelated partstemperatureofCalculation and reasonable correction is to improve the surface of testing equipment.temperatureThe key link of accuracy. But in the field.equipmentinfraredWhen testing, due to the detection conditions andenvironmentThe influence of change, may lead to the same equipment due to test strip.Different pieces, and get different results. Therefore, in order to improveinfraredThe accuracy of detection must be checked on site.measureprocessOr in the analysis and processing of the test results, take corresponding countermeasures and measures or choose good tests.Conditions, or make reasonable corrections to the test site results. Generally, we need to follow the following conditions and influences.Specific applicationinfrared radiation thermometer:

 

Influence of operation state of electrical equipment;

 

Electrical equipmentbreakdownUsually.electric currentEffect-induced feverbreakdown(conductive loopbreakdown-feverpowerand

loadelectric currentThe square of the value is proportional.), andvoltageEffect-induced feverbreakdown(insulatemediumbreakdown-feverpowerAnd operationvoltageIs proportional to the square of.)。 Therefore, the operation of the equipmentvoltageAnd loadelectric currentThe size of the will directly affect theinfraredDetection andbreakdownThe effect of diagnosis. releasedrain currentIncrease, can causehigh-pressureenvironment divisionvoltageUneven. If there is no load running or the load is low, it will make the equipmentbreakdownFever is not obvious, even if there is a serious one.breakdownIt is also impossible to be exposed in the form of characteristic thermal anomalies. Only when the equipment is rated.voltageUnder the operation, and the greater the load, the more serious the fever and temperature rise.breakdownThe more obvious the characteristic thermal anomaly of the point is exposed. As a result, in progressinfraredWhen testing, in order to obtain reliable testing results, we should try our best to ensure that the equipment is rated.voltageAnd even if continuous full-load operation cannot be achieved, an operation scheme should be worked out so that before and after inspection.process, can make the equipment run at full capacity for a period of time, make the equipmentbreakdownParts have enough heating time, and ensure its surface to achieve a stable temperature rise. Electrical equipmentbreakdowninfraredAt the time of diagnosis,breakdownThe judgment standard is often based on the rated equipment.electric currentWhen the temperature rise is based on, so the actual operation when testing.electric currentLess than ratedelectric currentWhen, should be the actual scene.measureEquipment ofbreakdownPoint temperature rise is converted to rated value.electric currentTemperature rise of.

 

Equipment surfaceemissivityThe impact of:

 

anyInfrared measurementGauges are all made bymeasureElectrical equipment surfaceinfraredradiationpower, to get the equipment.temperature

Informative. And atinfrareddiagnoseinstrumentReceive a message from a targetinfraredradiationpowerIn the same case, due to the surface of the targetemissivityDifferent, will get different test results. That is to say, the sameradiationpower,emissivityThe lower it is, the more it will be.showThe highertemperature. Due to the surface of the objectemissivityMainly depends on the material properties and surface state.(such as surface oxidation,coatingMaterials,roughnessAnd dirty state, etc.)。 So for application,Infrared measurementamountinstrumentaccuratelymeasureElectrical equipmenttemperature, you must know the subject'semissivityValue, and use this value as a calculation.temperatureImportant parameter input ofcomputerOr adjustInfrared measurementInstrumentalε correction value, so that themeasureoftemperatureOutput value progressemissivityCorrection. eliminateemissivityTwo countermeasures to influence the test results: when usinginfrared radiation thermometergo onmeasureWhen, tolaunchMake corrections to find out the surface of the tested equipment parts.emissivityValue progressionemissivityCorrection, so as to obtain a reliableTemperature measurementAs a result, the reliability of detection is improved; with regard toinfraredDetectedbreakdownFrequent equipment parts, in order to make the test results have good comparability, can use the method of coating appropriate paint to increase and stabilize them.emissivityValue, in order to obtain the truth of the surface of the measured equipment.temperature.

 



ltdCopyright 2023 All rights reserved [Hubei ICP No.2022003753 -2]